Spec Sheet
HARDWARE SPECIFICATIONS:
Dimensions: 215 x 120 x 95 mm (125 mm including handle), Scan Width - 195 mm (including light margins)
Weight: 1kg
Construction: Cast aluminum, black ABS plastic
Interface: USB
Power: Current Draw - 180mA
Nominal Measuring 8mil, 10mil and 20mil.
Aperture: The software automatically identies the symbology/nominal bar size (X dimension) and adjusts the
aperture size in order to comply with the symbology specications and International Standards.
Wavelength of Light: 660 nanometers
GENERAL INFORMATION:
Print of Analysis: A printed report can be produced on any connected printer. Printouts can be produced for the main
verication information (including: Decoded Number, Time & Date, Number of Scans, Code Type,
Average ISO/ANSI Grade, Average Bar Gain, Magnication, Check Character, Light margins and
Grading Percentage Value).
Standard Accessories: Transit Case, USB Cable, Calibration Sheet, Start-up Guide, Software CD, Compliance Certicates.
System Requirements: Apple Macintosh running OS X 10.2 or later.
ISO/ANSI verier aperture size:
Aperture X Dimension Typical Use
5mil Less than 13mil Non EAN.UCC Symbologies
10mil 13 to 25mil Small ITF-14 and all UCC/EAN-128 codes
20mil greater than 25mil Large ITF-14 codes
[For all UPC and EAN retail codes the EAN.UCC specication requires that a 6mil aperture should be used.]
SOFTWARE SPECIFICATIONS
Symbologies Veried:
EAN.UCC SYMBOLOGIES: EAN-8, EAN-13 (with or without addons), ITF-14/Case Code, RSS (all
symbologies), UCC/EAN-128, UPC-A, UPC-E (with or without addons).
OTHER SYMBOLOGIES: Code 39, Code 93, Code128, Codabar, ITF, MSI Plessey.
Analysis Performed on
Full ISO/ANSI Parameter Analysis (Rmin, Rmax, Global Threshold, Symbol Contrast, Min Edge ,
Relevant Symbologies:
Contrast, Modulation, Defects, Decodability, Decode), Average Bar Gain, Check Digit Validation,
Control Characters and Structure Checking, Data Length, Nominal Bar Width Analysis (X Dimension),
Symbol Structure including Parity, Subsets & Start/Stop Characters, Light Margin Validation, Wide to
Narrow Ratio Display and Validation.
Diagnostic Windows:
Details Results Window, Scan Reectance Prole, Summary Window, Traditional Results Window.
Logging:
Scan Saving and Loading - stores complete details of scan le data.
This allows for remote diagnostics and also for increased traceability.
Calibration Logging:
A record of date and time to show when the hardware has been calibrated is kept - vital for ISO 9000
records.
Congurable Options:
Audible Warnings, Calibration Expiry Period, Changeable Pass / Fail and Warning Colours, Check Digit
Validation (Code 39, Codabar, ITF), File Saving, Multi-Scan Averaging, Pass Grade, Print Options,
Window sizes and positions.
Error Messages:
Check Digit Error, Incorrect Wide to Narrow Ratio, Print Quality Failure, Light Margin Error, Reference
Decode Algorithm Error, Structure Error, Unsuitable X Dimension.
(Latest software updates can always be downloaded free from
All trademarks are acknowledged as belonging to their respective companies.
Due to Axicon’s continuing product improvement programs, specications and features herein are subject to change without notice.
For more information contact:
April 2005 - 7000 MAC UK
Axicon Auto ID Ltd
Church Road, Weston on the Green,
Bicester, Oxfordshire, OX25 3QP, United Kingdom
Tel.: +44 (0) 1869 351155, Fax: +44 (0) 1869 351205
Email: sales@axicon.com www.axicon.com