Datasheet
108-98014 Rev. C
All specications subject to change. Consult Tyco Electronics for latest specications. 12 of 18
Telecom-, Signal and RF Relays
Cradle Relay S V23054/V23062
AXICOM
Instructions for Impulse Operation
The maximum voltage stated in the table (page 6) can be increased for impulse operation as follows:
U
II Impuls
= U
II tamb
. q
U
II tamb
= Maximum continuous voltage at ambient temperature t
amb
q = Factor
The impulse voltage must not exceed 80% of the test voltage (winding/frame or winding/winding) or not to exceed the
max. voltage as listed in the table (page 6) by no more than 2.3 told.
Ift
ED
≤
3 s then q =
Ift
ED
= Pulse width
t
2
= Cycle time
If t
ED
> 3 s the value of q must be obtained from the nomograph (next page).
Examples of various periodic pulse trains (energizing side)
1. Periodic recurrence of one energizing pulse
2. Periodic recurrence of two unequal energizing pulses
t
ED
= t
I
+ t
II
t
I
+ t
II
= Pulse widths within one cycle