Datasheet

108-98007 Rev A
All specications subject to change. Consult Tyco Electronics for latest specications. 5 of 12
Telecom-, Signal and RF Relays
D2n V23105 Relay
AXICOM
Coil Operating Range
U
nom
= Nominal coil voltage
U
max.
= Upper limit of the operative range of the coil voltage (limiting
voltage) when coils are continously energized
U
op. min.
= Lower limit of the operative range of
the coil voltage (reliable operate voltage)
U
rel. min.
= Lower limit of the operative range of
the coil voltage (reliable release voltage)
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
2.2
2.4
2.6
2.8
3.0
-30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110 120
550 mW coil
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
2.2
2.4
2.6
2.8
3.0
-30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110 120
150 mW coil
0
0.2
0.4
0.6
0.8
1
1.2
1.4
1.6
1.8
2
2.2
2.4
2.6
2.8
3
-30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110 120
200 mW coil
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
2.2
2.4
2.6
2.8
3.0
-30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110 120
400 mW coil
Umax. at 0 A
Umax. at 2 x 2 A
Umax. at 2 x 1 A
Unom. nominal coil voltage
Uop. min.
Urel. min.
Ambient Temperature [°C]
Coil Voltage [U/Unom]
Umax. at 0 A
Umax. at 2 x 2 A
Umax. at 2 x 1 A
Unom. nominal coil voltage
Uop. min.
Urel. min.
Ambient Temperature [°C]
Coil Voltage [U/Unom]
Umax. at 0 A
Umax. at 2 x 2 A
Umax. at 2 x 1 A
Unom.
Uop. min.
Urel. min.
Ambient Temperature [°C]
Coil Voltage [U/Unom]
Umax. at 0 A
Umax. at 2 x 2 A
Umax. at 2 x 1 A
Unom.
Uop. min.
Urel. min.
Ambient Temperature [°C]
Coil Voltage [U/Unom]
150 mW
200 mW
400 mW
550 mW