Datasheet
108-98015 Rev. C
All specications subject to change. Consult Tyco Electronics for latest specications. 10 of 14
Telecom-, Signal and RF Relays
Cradle Relay P V23003
AXICOM
Contact Data
Ordering code block 3 B104/B110 B604/B610 C104/C110 C404/C410 F104 ... F107
Number of contacts and Type max. 4 changeover contacts, 2 break contacts or 2 make contacts
Contact assembly single contacts bifurcated contacts single contacts
Contact material
silver,
gold-ashed
gold F
silver,
gold-ashed
gold F
silver,
gold-ashed
Max. switching voltage 150 Vdc 36 Vdc 150 Vdc 36 Vdc 250 Vdc
125 Vac 30 Vac 125 Vac 30 Vac 250 Vac
Max. switching current 2 A 0.2 A 2 A 0.2 A 5 A
Max. switching capacity
35 to 70 W
see load limit
curve page 10
50 VA
5 W
5 VA
35 to 70 W
see load limit
curve page 10
50 VA
5 W
5 VA
50 to 140 W
see load limit
curve page 10
500 VA
Max. continuous current at
max. ambient temperature
2 A 5 A
Max. DC Load Breaking Capacity
Safe breaking, no stationary arc
Contact material silver, gold-ashed
Safe breaking, no stationary arc
Contact material silver, gold-ashed
for contact sets F1xx
I = switching current
U = switching voltage
I = switching current
U = switching voltage
for contact sets B1xx and C1 xx