User Manual

108-98012 Rev. C
All specications subject to change. Consult Tyco Electronics for latest specications. 7 of 23
Telecom-, Signal and RF Relays
Cradle Relay N V23154/V23162
AXICOM
Coil number
Monostable, 1 coil
711 = 5 V nominal voltage
712 = 6 V
717 = 12 V
721 = 24 V
726 = 48 V
734 = 60 V
735 = 110 V
703 = 125 V
V23154
Identication of the
Cradle N Relay, dust protected
Relay type
C0 = Size I,
for plug-in and screw xing, hand solder terminals silver-plated,
with earth terminal, dust-protected
D0 = Size II,
for plug-in and screw xing, hand solder terminals silver-plated,
with earth terminal, dust-protected
M0 = Size I,
for printed circuit mounting, with earth terminal, dust-protected
N0 = Size II,
for printed circuit mounting, with earth terminal, dust-protected
M4 = Size I,
for printed circuit mounting, without earth terminal, dust-protected
N4 = Size II,
Contact set / type of contact
see page 19
Ordering example:
V23154-D0721-B110
Cradle relay N, size II, plug-in, dust-protected, hand solder terminals, silver-plated, coil 24 Vdc,
4 changeover contact set, single contacts, contact material silver, gold-ashed.
Note:
The ordering scheme enables a multitude of variations. However, not all variations are dened as construction specica-
tions (ordering code) and thus in the current delivery program.
Relay Code