User Manual

108-98012 Rev. C
All specications subject to change. Consult Tyco Electronics for latest specications. 19 of 23
Telecom-, Signal and RF Relays
Cradle Relay N V23154/V23162
AXICOM
Contact Data
Ordering code block 3
B104/B110/
B112
B604/B610/
B612
C104/C110/
C112
C404/C410 F104 ... F107
Number of contacts and Type max. 4 changeover contacts, 2 break contacts or 6 make contacts
Contact assembly single contacts bifurcated contacts single contacts
Contact material
silver,
gold-ashed
gold F
silver,
gold-ashed
gold F
silver,
gold-ashed
Max. switching voltage 150 Vdc 36 Vdc 150 Vdc 36 Vdc 250 Vdc
125 Vac 30 Vac 125 Vac 30 Vac 250 Vac
Max. switching current 2 A 0.2 A 2 A 0.2 A 5 A
Max. switching capacity
35 to 70 W
see load limit
curve below
50 VA
5 W
5 VA
35 to 70 W
see load limit
curve below
50 VA
5 W
5 VA
50 to 140 W
see load limit
curve below
500 VA
Max. continuous current at
max. ambient temperature
2 A 5 A
70 W
40 W
150
120
100
80
60
50
40
30
V
_
U
0,3 0,4 0,5 0,6 0,8 1 1,5 2A
I
250
200
150
100
80
60
50
40
30
20
V
_
100 W
140 W
50 W
0,2 0,3 0,4 0,5 0,6 0,8 1 1,5 2 3 4 5A
I
U
Max. DC Load Breaking Capacity
Safe breaking, no stationary arc
Contact material silver, gold-ashed
for contact sets F1xx
I = switching current
U = switching voltage
for contact sets B1xx and C1 xx