Datasheet

108-98002 Rev. E
All specications subject to change. Consult Tyco Electronics for latest specications. 3 of 15
Telecom-, Signal and RF Relays
P2 V23079 Relay
AXICOM
2 pole telecom / signal relay, polarized,
Through Hole Type (THT) or
Surface Mount Technology (SMT),
Relay types: non-latching with 1 coil
latching with 2 coils
latching with 1 coil
ROHS compliant (Directive 2002/95/EC) as per
product date code 0427.
Features
Standard telecom relay (ringing and test access)
Slim line 15 x 7.5 mm, 0.590 x 0.295 inch
Switching current 5 A
2 changeover contacts (2 form C / DPDT)
Bifurcated contacts
Immersion cleanable
High sensitivity results in low nominal power
consumption 140 mW for non-latching and latching
with 2 coils 70 mW for latching with 1 coil
For single coil version:
- Surge voltage resistance between
contact and coil for single coil version:
- 2.5 kV (2 / 10 µs) meets the Telcordia
Requirement GR-1089
- 1.5 kV (10 / 160 µs) meets FCC Part 68
Typical applications
Communications equipment linecard application
(ringing and test access)
PABX
Voice over IP
Ofce equipment
Measurement and control equipment
Automotive equipment
CAN bus, keyless entry, speaker switch
Medical equipment
Consumer electronics
Set Top Boxes, HiFi
Options
1500 Vrms between open contacts
Insulation category
Basic insulation according IEC / EN 60950
Working voltage ≤ 300 Vrms
Mains supply voltage ≤ 250 Vrms
Repetitive peak voltage 2500 V
Pollution degree Internal: 1
External: 2
Flammability classication V-0
Maximum operating temperature 85 °C