Datasheet
108-98002 Rev. E
All specications subject to change. Consult Tyco Electronics for latest specications. 3 of 15
Telecom-, Signal and RF Relays
P2 V23079 Relay
AXICOM
2 pole telecom / signal relay, polarized,
Through Hole Type (THT) or
Surface Mount Technology (SMT),
Relay types: non-latching with 1 coil
latching with 2 coils
latching with 1 coil
ROHS compliant (Directive 2002/95/EC) as per
product date code 0427.
Features
• Standard telecom relay (ringing and test access)
• Slim line 15 x 7.5 mm, 0.590 x 0.295 inch
• Switching current 5 A
• 2 changeover contacts (2 form C / DPDT)
• Bifurcated contacts
• Immersion cleanable
• High sensitivity results in low nominal power
consumption 140 mW for non-latching and latching
with 2 coils 70 mW for latching with 1 coil
• For single coil version:
- Surge voltage resistance between
contact and coil for single coil version:
- 2.5 kV (2 / 10 µs) meets the Telcordia
Requirement GR-1089
- 1.5 kV (10 / 160 µs) meets FCC Part 68
Typical applications
• Communications equipment linecard application
(ringing and test access)
PABX
Voice over IP
• Ofce equipment
• Measurement and control equipment
• Automotive equipment
CAN bus, keyless entry, speaker switch
• Medical equipment
• Consumer electronics
Set Top Boxes, HiFi
Options
• 1500 Vrms between open contacts
Insulation category
Basic insulation according IEC / EN 60950
Working voltage ≤ 300 Vrms
Mains supply voltage ≤ 250 Vrms
Repetitive peak voltage 2500 V
Pollution degree Internal: 1
External: 2
Flammability classication V-0
Maximum operating temperature 85 °C