Datasheet

108-98002 Rev. E
All specications subject to change. Consult Tyco Electronics for latest specications. 10 of 15
Telecom-, Signal and RF Relays
P2 V23079 Relay
AXICOM
Contact Data
Number of contacts and type 2 changeover contacts
Contact assembly Bifurcated contacts
Contact material Silver nickel, gold-covered
Limiting continuous current at max. ambient temperature 2 A
Maximum switching current 5 A
Maximum swichting voltage 220 Vdc
250 Vac
Maximum switching capacity 60 W, 62.5 VA
Thermoelectric potential < 10 µV
Minimum switching voltage 100 µV
Initial contact resistance / measuring condition: 10 mA / 20 mV < 50 mΩ
Electrical endurance at 12 V / 10 mA
at 6 V / 100 mA
at 60 V / 500 mA
at 30 V / 1000 mA
at 30 V / 2000 mA
typ. 5 x 10
7
operations
typ. 1 x 10
7
operations
typ. 5 x 10
5
operations
typ. 1 x 10
6
operations
typ. 2 x 10
5
operations
Mechanical endurance typ. 10
8
operations
UL contact ratings 220 Vdc / 0.24 A - 60 W
125 Vdc / 0.24 A - 30 W
250 Vac / 0.25 A - 62.5 VA
125 Vac / 0.5 A - 62.5 VA
30 Vdc / 2 A - 60 W
Max. DC Load Breaking Capacity
DC Voltage [Vdc]
DC current [A]
resistive load