AXICOM Telecom-, Signal and RF Relays P1 V23026 Relay 108-98009 • Aug. 08 Rev.
AXICOM 108-98009 Rev. F Telecom-, Signal and RF Relays P1 V23026 Relay Disclaimer While Tyco Electronics has made every reasonable effort to ensure the accuracy of the information in this datasheet, Tyco Electronics does not guarantee that it is error-free, nor does Tyco Electronics make any other representation, warranty or guarantee that the information is accurate, correct, reliable or current.
AXICOM 108-98009 Rev. F Telecom-, Signal and RF Relays P1 V23026 Relay 1 pole telecom / signal relay, polarized, Through Hole Type (THT) or Surface Mount Technology (SMT), Relay types: non-latching with 1 coil latching with 2 coils latching with 1 coil ROHS compliant (Directive 2002/95/EC) as per product date code 0429. Features – Directly triggerable with TTL standard modules such as ALS, HCT and ACT – Slim line 13.5 x 7.85 mm, 0.531 x 0.
AXICOM 108-98009 Rev. F Telecom-, Signal and RF Relays P1 V23026 Relay Dimensions Dimensions in mm THT V23026-x1xxx-B201 L W H T T1 T2 S S1 S2 mm 13.00 ± 0.10 7.60 ± 0.10 6.90 – 0.20 3.50 – 0.20 N/A 5.08 ± 0.15 0.30 ± 0.10 N/A N/A SMT V23026-x1xxx-B201 inch 0.512 ± 0.004 0.299 ± 0.004 0.272 – 0.008 0.138 – 0.008 N/A 0.200 ± 0.006 0.012 ± 0.004 N/A N/A mm 13.40 ± 0.10 7.75 ± 0.10 8.00 – 0.20 N/A 10.90 – 0.50 5.08 ± 0.15 N/A 0.85 ± 0.10 0.20 – 0.15 THT Version inch 0.528 ± 0.004 0.305 ± 0.004 0.
AXICOM 108-98009 Rev. F Telecom-, Signal and RF Relays P1 V23026 Relay Coil Operating Range Unom Coil Voltage [U/Unom] 65 mW 130 mW Umax. at 0 A Umax. at - 1 A Umax. at 0 A = Nominal coil voltage = Upper limit of the operative range of Umax. the coil voltage (limiting voltage) when coils are continously energized = Lower limit of the operative range of Uop. min. the coil voltage (reliable operate voltage) = Lower limit of the operative range of Urel. min.
AXICOM 108-98009 Rev. F Telecom-, Signal and RF Relays P1 V23026 Relay Coil Data (values at 23 °C) Nominal voltage Unom Vdc Operate/set voltage range Ordering Information Release/ reset voltage Minimum Coil power Coil Resistance Minimum voltage Umin Maximum voltage Umax Vdc Vdc Vdc mW Ω / ± 10 % 8.80 14.50 25.50 35.00 50.00 0.30 0.50 0.90 1.20 2.40 66 68 70 64 128 137 370 1165 2250 4500 THT, non-latching, 1 coil 3 2.25 5 3.75 9 6.75 12 9.00 24 18.
AXICOM 108-98009 Rev. F Telecom-, Signal and RF Relays P1 V23026 Relay Contact Data Number of contacts and type Contact assembly 1 changeover contact Bifurcated contact Contact material Palladium nickel, gold-rhodium covered Limiting continuous current at max.
AXICOM 108-98009 Rev.
AXICOM 108-98009 Rev.
AXICOM 108-98009 Rev. F Telecom-, Signal and RF Relays P1 V23026 Relay Packing Dimensions in mm 13.8±0.2 Tube for THT version 40 relays per tube 2‘000 relays per box 11.6±0.2 Tape and reel for SMT version 480 relays per reel 2‘400 per box Reel dimension All specifications subject to change. Consult Tyco Electronics for latest specifications.
AXICOM 108-98009 Rev. F Telecom-, Signal and RF Relays P1 V23026 Relay IM Relays D2n Relays 4th generation slim line – low profile polarized 2 c/o telecom signal relay with bifurcated contacts, available as non latching or latching relay with 1 coil. Nominal voltage range from 1.5 ... 24 V, coil power consumption of 50 ... 200 mW, latching relays with 1 coil 100 mW. The IM relay is available as through hole and surface mount type (J-Legs and Gull Wings) and capable to switch loads up to 60 W/62,5 VA.
Tyco Electronics Logistics AG Werk Axicom Au Seestrasse 295 CH-8804 Au-Wädenswil / Switzerland Phone +41 44 782 91 11 Fax +41 44 782 90 00 E-mail: axicom@tycoelectronics.com Tyco Electronics Paulsternstrasse 26 D-13629 Berlin / Germany Phone +49 30 386 38573 Fax +49 30 386 38575 E-mail: axicom@tycoelectronics.com Tyco Electronics EC Trutnov s.r.o. Komenského 821 CZ-541 01 Trutnov / Czech Republic E-mail: axicom@tycoelectronics.