Datasheet

108-98001 Rev. G
All specications subject to change. Consult Tyco Electronics for latest specications. 3 of 15
Telecom-, Signal and RF Relays
IM Relay
AXICOM
Slim line AND low prole
2 pole telecom/signal relay, polarized
Through Hole Types (THT), standard version
with 5.08 mm, narrow version with 3.2 mm between the
terminal rows or Surface Mount Type (SMT)
Relay types: non-latching with 1 coil
latching with 1 coil
ROHS compliant (Directive 2002/95/EC) as per
product date code 0438.
Features
Telecom/signal relay (dry circuit, test access,
ringing)
Slim line 10 x 6 mm, 0.39 x 0.24 inch
Low prole 5.65 mm, 0.222 inch
Minimum board-space 60 mm
2
Switching current 2 A / 5 A
2 changeover contacts (2 form C / DPDT)
Bifurcated contacts, gold plated
High sensitivity results in low nominal power
consumption
140 mW for non latching standard
100 mW for latching version and non latching high
sensitive version
Ultra high sensitive type 50 mW for non latching
High surge capability (1.2/50 µs and 10/700 µs)
meets Telcordia GR 1089, FCC Part 68 and ITU-T
K20, 21, 45
1500 V between open contacts
2500 V between coil and contacts
High mechanical shock resistance
up to 300 G functional, up to 500 G survival
Hermetically sealed (RT V)
Typical applications
Communications equipment
Linecard application – analog, ISDN, xDSL, PABX
Voice over IP
Ofce and business equipment
Measurement and control equipment
Consumer electronics, Set top boxes, HiFi
Medical equipment
Options
Surge capability 2500 V between open contacts
Insulation category
Supplementary insulation according IEC / EN 60950
Working voltage 300 Vrms
Mains supply voltage 250 Vrms
Repetitive peak voltage 2500 V
Pollution degree Internal: 1
External: 2
Flammability classication V-0
Maximum operating temperature 85 °C