AXICOM Telecom-, Signal and RF Relays IM Relay 108-98001 • Sep. 07 Rev.
AXICOM Telecom-, Signal and RF Relays 108-98001 Rev. G IM Relay Disclaimer While Tyco Electronics has made every reasonable effort to ensure the accuracy of the information in this datasheet, Tyco Electronics does not guarantee that it is error-free, nor does Tyco Electronics make any other representation, warranty or guarantee that the information is accurate, correct, reliable or current.
AXICOM Telecom-, Signal and RF Relays 108-98001 Rev. G IM Relay Slim line AND low profile 2 pole telecom/signal relay, polarized Through Hole Types (THT), standard version with 5.08 mm, narrow version with 3.2 mm between the terminal rows or Surface Mount Type (SMT) Relay types: non-latching with 1 coil latching with 1 coil ROHS compliant (Directive 2002/95/EC) as per product date code 0438. Features • Telecom/signal relay (dry circuit, test access, ringing) • Slim line 10 x 6 mm, 0.39 x 0.
AXICOM Telecom-, Signal and RF Relays 108-98001 Rev. G IM Relay Dimensions Dimensions in mm IM THT Standard L W H T T1 T2 D1 D2 Tw S mm 10.00 ± 0.08 6.00 ± 0.08 5.65 – 0.20 3.2 N/A 5.08 ± 0.10 3.20 ± 0.15 2.20 ± 0.15 0.40 0.30 ± 0.05 inch 0.393 ± 0.003 0.236 ± 0.003 0.222 – 0.008 0.125 N/A 0.200 ± 0.004 0.126 ± 0.006 0.087 ± 0.006 0.015 0.011 ± 0.002 mm 10.00 ± 0.08 5.70 ± 0.30 5.80 ± 0.08 3.2 N/A 3.20 ± 0.10 3.20 ± 0.15 2.20 ± 0.15 0.4 0.30 ± 0.05 IM THT Narrow inch 0.393 ± 0.003 0.224 ± 0.
AXICOM Telecom-, Signal and RF Relays 108-98001 Rev. G IM Relay Coil Operating Range 50 mW coil 100 mW coil 3.4 3.2 3 Coil Voltage [U/Unom] Umax. at 0 A Umax. at 2 x 1 A 2.8 2.6 Umax. at 0 A 2.4 2.2 2 1.8 Umax. at 2 x 2 A 1.6 1.4 1.2 Unom. nominal coil voltage 1 0.8 Uop min. 0.6 0.4 Unom = Umax. = Uop. min. = Urel. min.
AXICOM Telecom-, Signal and RF Relays 108-98001 Rev. G IM Relay Coil Data (values at 23 °C) Nominal voltage Unom Vdc Operate/set voltage range Ordering Information Release/ reset voltage Minimum Coil power Coil Resistance Ω / ± 10 % Relay code Tyco part number Minimum voltage Umin Maximum voltage Umax Vdc Vdc Vdc mW 3.60 7.20 10.80 12.10 14.50 21.70 28.90 48.50 0.15 0.30 0.45 0.50 0.60 0.90 1.20 2.
AXICOM Telecom-, Signal and RF Relays 108-98001 Rev. G IM Relay Coil Data (values at 23 °C) Nominal voltage Unom Operate/set voltage range Release/ reset voltage Minimum Coil power Coil Resistance Vdc mW Ω / ± 10 % 4.30 8.40 12.90 14.30 17.10 25.70 34.30 48.50 -1.13 -2.25 -3.38 -3.75 -4.50 -6.75 -9.00 -18.00 100 100 100 100 100 100 100 200 4.30 8.40 12.90 14.30 17.10 25.70 34.30 48.50 -1.13 -2.25 -3.38 -3.75 -4.50 -6.75 -9.00 -18.00 4.30 8.40 12.90 14.30 17.10 25.70 34.30 48.50 4.30 8.
AXICOM Telecom-, Signal and RF Relays 108-98001 Rev. G IM Relay Coil Data (values at 23 °C) Nominal voltage Unom Vdc Operate/set voltage range Ordering Information Release/ reset voltage Minimum Coil power Coil Resistance Ω / ± 10 % Relay code Tyco part number Minimum voltage Umin Maximum voltage Umax Vdc Vdc Vdc mW 8.70 13.10 14.60 35.00 57.80 0.30 0.45 0.50 1.20 2.
AXICOM Telecom-, Signal and RF Relays 108-98001 Rev. G IM Relay Coil Data (values at 23 °C) Nominal voltage Unom Vdc Operate/set voltage range Minimum voltage Umin Maximum voltage Umax Vdc Vdc Ordering Information Release/ reset voltage Minimum Coil power Coil Resistance Vdc mW Ω / ± 10 % Relay code Tyco part number Ultra High Sensitive Version SMT Gull Wings non-latching 1 coil 3 4.5 5 12 2.55 3.83 4.25 10.20 10.80 16.20 18.00 43.20 0.30 0.45 0.50 1.
AXICOM Telecom-, Signal and RF Relays 108-98001 Rev. G IM Relay Contact Data Number of contacts and type Contact assembly Contact material Limiting continuous current at max.
AXICOM Telecom-, Signal and RF Relays 108-98001 Rev.
AXICOM Telecom-, Signal and RF Relays 108-98001 Rev.
AXICOM Telecom-, Signal and RF Relays 108-98001 Rev. G IM Relay Packing Dimensions in mm Tube for THT version 50 relays per tube 1‘000 relays per box Tape and reel for SMT version 1’000 relays per reel 1’000 or 5’000 relays per box Reel dimension All specifications subject to change. Consult Tyco Electronics for latest specifications.
AXICOM Telecom-, Signal and RF Relays 108-98001 Rev. G IM Relay IM Relays D2n Relays 4th generation slim line – low profile polarized 2 c/o telecom signal relay with bifurcated contacts, available as non latching or latching relay with 1 coil. Nominal voltage range from 1.5 ... 24 V, coil power consumption of 50 ... 200 mW, latching relays with 1 coil 100 mW. The IM relay is available as through hole and surface mount type (J-Legs and Gull Wings) and capable to switch loads up to 60 W/62,5 VA.
Tyco Electronics Logistics AG Werk Axicom Au Seestrasse 295 CH-8804 Au-Wädenswil / Switzerland Phone +41 44 782 91 11 Fax +41 44 782 90 00 E-mail: axicom@tycoelectronics.com Tyco Electronics Paulsternstrasse 26 D-13629 Berlin / Germany Phone +49 30 386 38573 Fax +49 30 386 38575 E-mail: axicom@tycoelectronics.com Tyco Electronics EC Trutnov s.r.o. Komenského 821 CZ-541 01 Trutnov / Czech Republic E-mail: axicom@tycoelectronics.