Operating instructions
TM 11-5865-229-12
e. Program Module Assembly Installation.
Perform the following procedure to install the program
module assembly in the RT.
Leave replacement program module assembly in the static barrier bag until you are ready to install
it.
Carefully remove replacement program module assembly from static barrier bag. Remember to handle
it by the cover only.
Line up program module assembly CCA with
Carefully push replacement program module
mated with connector on RT.
CCA grooves on the RT,
assembly straight into RT until plug on assembly is
Tighten four captive screws on program module assembly with torque screwdriver to 5 ±1 in/lb.
Perform the operational test (paragraph 3–9) to make sure the CM Set is working properly.
3-15. CCU KNOB AND LAMP REMOVAL AND INSTALLATION.
a. Tools and Materials Required.
Tool Kit, Electronic Equipment TK-101/G
Screwdriver, .032 x 11/64 x 3 in
L Hex Wrench, .050