Instruction Manual
14
R2-Series User’s Manual 11/13/12
MKTF - 212
NUMBER IDENTIFICATION
1. SOLENOID VALVE – TURNS FEED WATER ON/OFF
2. 5 MICRON SEDIMENT – REDUCES PARTICULATES
3. PRESSURE GAUGE – MEASURES FEED PRESSURE
4. PRESSURE GAUGE – MEASURES PRESSURE AFTER FILTER
5. PRESSURE GAUGE – MEASURES PUMP PRESSURE
6. PRESSURE GAUGE – MEASURES CONCENTRATE PRESSURE
7. COMPUTER CONTROLLER – CONTROLS RO SYSTEM FUNCTIONS
8. CONCENTRATE VALVE– CONTROLS FLOW OF CONCENTRATE (WASTE) WATER
9. RO PUMP AND MOTOR – PRESSURIZES RO SYSTEM
10. THROTTLE VALVE – CONTROLS FLOW OF PUMP
11. FLOW METER – MEASURES FLOW OF PERMEATE WATER
12. FLOW METER – MEASURES FLOW OF CONCENTRATE (WASTE) WATER
13. LOW PRESSURE SWITCH – TURNS OFF RO PUMP WHEN FEED PRESSURE FALLS BELOW
SET POINT
14. PERMEATE CHECK VALVE – PROTECTS MEMBRANE ELEMENTS FROM BACKPRESSURE
15. PRESSURE VESSELS – HOUSES MEMBRANE ELEMENTS
16. HIGH PRESSURE SWITCH – TURNS THE PUMP OFF AT A PRE-DETERMINED HIGH PSI PUMP
PRESSURE
17. PERMEATE SAMPLE VALVE- MEASURES THE QUALITY OF EACH MEMBRANE
18. CLEANING PORT VALVE- PROVIDES ACESS TO CLEAN THE MEMBRANES