Manual
17
MKTF - 211 07/26/12
NUMBER IDENTIFICATION
1. SOLENOID VALVE – TURNS ON/OFF FEED WATER
2. 5 MICRON SEDIMENT – REMOVES PARTICULATES
3. PRESSURE GAUGE – MEASURES FEED PRESSURE
4. PRESSURE GAUGE – MEASURES PRESSURE AFTER FILTERS
5. PRESSURE GAUGE – MEASURES PUMP PRESSURE
6. PRESSURE GAUGE – MEASURES CONCENTRATE PRESSURE
7. COMPUTER CONTROL – CONTROLS RO SYSTEM FUNCTIONS
8. RECYCLE VALVE – RECYCLES CONCENTRATE BACK TO FEED (IF APPLICABLE)
9. CONCENTRATE VALVE– CONTROLS FLOW OF CONCENTRATE (WASTE) WATER TO
THE DRAIN
10. RO PUMP AND MOTOR – PRESSURIZES RO SYSTEM
11. THROTTLE VALVE – CONTROLS FLOW OF PUMP
12. FLOW METER – MEASURES FLOW OF PERMEATE WATER
13. FLOW METER – MEASURES FLOW OF CONCENTRATE (WASTE) WATER
14. FLOW METER – MEASURES FLOW OF CONCENTRATE RECYCLE WATER
15. PRESSURE SWITCH – TURNS OFF RO PUMP WHEN FEED PRESSURE FALLS BELOW
15PSI
16. PERMEATE CHECK VALVE – PROTECTS MEMBRANE ELEMENTS FROM
BACKPRESSURE
17. PRESSURE VESSELS – HOUSES MEMBRANE ELEMENTS
18. PERMEATE SAMPLE VALVE- MEASURES THE QUALITY OF EACH MEMBRANE