User`s manual
19
ENGF-110 REV. A 01/11 © 2011 AXEON Water Technologies
NOTE: IF THE TDS OF THE FEED WATER EXCEEDS 1000 PPM OF NACL,
A LARGER FLOW RESTRICTOR SHOULD BE USED TO EXTEND THE
MEMBRANE LIFE.
4. It is important to maintain and/or replace the carbon block regularly since the Thin
Film Composite membranes are chlorine sensitive. Irreversible damage will occur
with any chlorine present in the feed water. For additional information please review
the manufacturer’s membrane specification sheets.
5. The product line has a one way check valve installed. The check valve should be
checked regularly and replaced if not properly sealing.
6. Keep the feed water temperature above 4°C (36°F).
NOTE: EXTREMELY COLD FEED WATER WILL LOWER THE PRODUCT
WATER OUTPUT AND INCREASE PUMP PRESSURE.