OPERATING DO’s & DON’Ts
DO:
Change the cartridge filters regularly
Monitor the system and keep a daily log
Run the system, as much as possible, on a continuous basis.
Always feed the pump with filtered water.
DON’T
Permit chlorine to enter or be present in the feed water.
Shut down the system for extended periods.
Operate the system with insufficient feed flow.
Operate the pump dry.
MAINTENANCE PROCEDURES
1. Periodically observe the quality and quantity of product water from the system.
NOTE: CHECK THE FEED WATER PRESSURE GOING INTO THE
REVERSE OSMOSIS MEMBRANE, A SIGNIFICANT DROP IN PRESSURE
COULD INDICATE A FOULED PRE-FILTER.
2. A 20% increase in TDS when checking the permeate water indicates possible
membrane damage and the membrane may need to be replaced.
3. It is suggested that a hand held TDS digital meter is used once per week to monitor
the water quality.