User's Manual

Table Of Contents
MBF-40 AMERICAS REPEATERS
PRODUCT DESCRIPTION AND USER’S MANUAL
www.cobham.com/wireless
Page | 2-40
Date: 14-Feb-16
Rev. 4.3
Cobham Wireless Coverage
Document number: 00071UM
To connect the Master and Slave (refer to the previous figure)
1. GND BOTH the Master and Slave units according to section 2.2.4.
2. Ensure good EMV protection according to section
2.1.7
3. Interconnect Master and Slave as follows:
2 high quality 50ohm coaxial (jumper) cables with N male connectors on both side
1 low loss, high quality 50ohm jumper cable with 7/16 male connectors on both side
1 standard straight CAT5 (or above) Ethernet cable with RJ45 connectors on both side
MASTER Port SLAVE Port Description CABLE Type (section 2.4.1)
SERVER LINK INPUT Jumper cable with 7/16 male
connectors
DL MS
DL MS DL intermediate
Connector Master-
Slave
RF Low Power 50ohm coaxial
(jumper) cable with N male
connectors
UL MS UL MS UL intermediate
Connector Master-
Slave
50ohm coaxial (jumper) cable
with N male connectors
IntraComm IntraComm If NO external alarms are
connected: LAN/ CAT5
(If external alarms are connected,
refer to section
2.4.4)
4. Route the following cables through the MASTER DONOR port and connect internally:
Cable Condition Details
Optic Fibre Always See section Error! Reference source not
found.
ETH (opt) If the unit is to be
connected to the
Ethernet
infrastructure
To the Controller ETH port.
See section
1.7.3
5. Connect the Server antenna to the SLAVE unit Server antenna port as illustrated.
6. Connect power, power-up, close and secure both units according to sections
2.2.8.1, 2.2.8.2 and
2.2.10.