Wet Cleaning
ATTENTION!
Invisible laser radiation might be emitted from disconnected fibers
or connectors. Do not stare into beams or
view directly with optical
instruments.
1. Lightly moisten a new lint-free wipe with 99% isopropyl alcohol. (Step 1 below).
Tip: Have a dry lint-free swab available for immediately drying after performing the wet-cleaning.
2. Lightly press and turn a clean lint-free swab in the moistened area of the wipe to
moisten the swab. It is important that the swab is not too wet. (Step 2 below).
3. Insert the moistened lint-free swab into the bulkhead adapter. Lightly press and
rotate several times in the same direction (Step 3 below).
Figure 8-1: Wet-Cleaning Technique
4. Immediately use a dry lint-free swab to clear any remaining alcohol residue.
NOTE: Do not re-use any of the wipes and/or swabs. Dispose of them properly.
5. Follow steps 3 to 6 of Dry Cleaning above
6. Re-inspect the Fiber using the Fiberscope. On the PC monitor, verify that there is no
contamination present on the connector end-face.
7. If the Fiber is still dirty, go back to step 1 (Wet Cleaning) and repeat the entire
process.
NOTE: The entire wet/dry cleaning cycle should only be used twice, if the Fiber is still dirty after two
cycles of wet/dry cleaning seek advice from the Axell Wireless Support Desk.