4. With the cleaning-head end
fully engaged in the connector,
push until an audible “click” is
heard
5. Without fully withdrawing the
cleaning head end push it in
again twice more, each time
until an audible “click” is heard.
6. Withdraw the “One Click”
cleaner and replace the
protective end cap.
7. Inspect the Fiber connector using a Fiberscope. On the PC monitor, verify that
there is no contamination present on the connector end-face.
8. If the connector is dirty, clean it with a wet cleaning technique followed
immediately by dry cleaning. This is to remove any remaining residue from the
wet clean (the following steps demonstrate a wet cleaning technique).