AXELL MBF-40 AMERICAS REPEATER
PRODUCT DESCRIPTION AND USER’S MANUAL
© Axell Wireless Ltd Doc. No. 00071UM Rev. 3.4 33
To connect the Master and Slave (refer to the previous figure)
1. GND BOTH the Master and Slave units according to section 3.5.
2. Ensure good EMV protection according to section
3.6.
3. Interconnect Master and Slave as follows:
2 high quality 50ohm coaxial (jumper) cables with N male connectors on both side
1 low loss, high quality 50ohm jumper cable with 7/16 male connectors on both side
1 standard straight CAT5 (or above) Ethernet cable with RJ45 connectors on both
side
MASTER Port SLAVE Port Description CABLE Type
(section 0)
SERVER LINK INPUT Jumper cable with
7/16 male
connectors
DL MS
DL MS
Downlink intermediate
connector Master-Slave
RF Low Power
50ohm coaxial
(jumper) cable with
N male connectors
UL MS UL MS
UL intermediate
connector Master-Slave
50ohm coaxial
(jumper) cable with
N male connectors
IntraComm IntraComm If NO external
alarms are
connected: LAN/
CAT5
(If external alarms
are connected, refer
to section
3.4.4)
4. Route the following cables through the MASTER DONOR port and connect internally:
Cable Condition Details
Optic Fibre Always
See section
ETH (opt) If the unit is to be
connected to the
Ethernet
infrastructure
To the Controller ETH port.
See section
1.7.3
5. Connect the Server antenna to the SLAVE unit Server antenna port as illustrated.
6. Connect power, power-up, close and secure both units according to sections
3.9,
3.10 and 3.11.