User Manual

Table Of Contents
AXELL MBF -40 AMERICAS REPEATERS
PRODUCT DESCRIPTION AND USER’S MANUAL
80 Doc. No. 00071UM Rev. 3.2 © Axell Wireless Ltd
Appendix A - US Specifications
Frequency Range
Uplink (UL)
Downlink (DL)
Operational BW
Composite Output
Power (*)
LTE700
Lower band
698-716MHz
728-746MHz
29MHz
+37 dBm
Upper band
776-787MHz
746-757MHz
29MHz
+37 dBm
800MHz (Sprint)
817-824 MHz
862-869 MHz
32MHz
+37 dBm
850MHz (Cellular)
824-849MHz
869-894MHz
32MHz
+37 dBm
1900MHz (PCS)
1850-1915MHz
1930-1995MHz
65MHz
+37 /+43 dBm**
1700MHz (AWS)
1710-1755MHz
2110-2155MHz
45MHz
+39 / +43 dBm**
General Parameters
Noise Figure
3dB Typical (maximum gain)
Ripple
±2dB
Propagation Delay
< 2µs
Gain UL/DL
Adjustable, in 1dB steps
System Impedance
50
Return loss at antenna
connections
>14dB
Antenna Connectors
DIN 7/16
No. of antenna orts
1 for single/dual/tri/quad band, 2 connectors for MIMO
Electrical ratings
115VAC 60Hz, -48VDC
Optical Parameters
Wavelength DL/UL
1310/1550nm
Max optical Loss
10dBo
F/O Connector
1 SC/APC for SISO, 2 for MIMO
Modulation Accuracy at nominal output power
GSM/GMSK
<2.5º RMS and <10º peak
EDGE/8-PSK
<3% EVM RMS
WCDMA/EVM
<12.5% RMS (composite according to ETSI TS 25.106 with TM1/64 DPCH
LTE/EVM
< 8% (composite according to 3GPP TS 136 106)
PkCDE
<-33dB (ETSI TS 25.106 with TM 1/64 DPCH and spreading factor 256)
Power Consumption
Single Band
Dual Band
Tri Band
Quad Band
140W
220W / 350W ***
350W
400W
Mechanical
Single Band
Dual Band
Tri Band
Quad Band
Dimensions
21.3” x 15” x 7.8”
540 x 382 x 198mm
21.3” x 15” x 7.8”
540 x 382 x 198 mm
21.3” x 15” x 12.3”
540 x 382 x 313 mm
21.3” x 15” x 12.3”
540 x 382 x 313 mm
Weight
44lbs (20kg)
48.5lbs (22kg)
76lbs (34kg)
82lbs (37kg)
Enclosure
Aluminum (IP65)
Environmental
EMC
FCC
Operating Temperature
-77 to +121ºF (-25 to +50ºC)
Storage Temperature
-86 to +158ºF (-30 to +70ºC)
Humidity
ETSI EN 300 019-2-4 (see compliance below)
Complies With
Radio
FCC part 15 Subpart B (2002), Class B, Radio frequency devices, Unintentional radiators
FCC part 24 Subpart E (2002), Personal communications services, Broadband PCS
Safety
UL 60 950-1, 1st Edition ”Information Technology Equipment
Safety - Part 1: General requirements"
UL 50, 11th Edition “Enclosures for Electrical Equipment”
* In repeaters that share a common downlink Fiber for 900MHz and 1800MHz a minimum of 4 carriers in each
band is required for the full composite output power to be attainable maintaining full ETSI compliance.
** The composite output power is model dependent.
*** Power consumption of all dual-band models except for MBF-4317-4319, is 220W. Power consumption for
MBF-4317-4319 is 350 W.
.