Figure 5-3: Example of MBF-40 Tri-Band Configuration window
3. In the Downlink:
• Verify the Amplifier for each band is ON.
• Set Attenuation to maximum value (15dB).
• Lower the Attenuation level step by step until the desired Output power
level is reached (Zero attenuation = maximum gain).
• Verify the Amplifier Saturation is GREEN.
4. In the Uplink:
• Verify the Amplifier for each band is ON.
• Set Attenuation equal to the value set in the DL (above).
• Verify the Amplifier Saturation is GREEN.
NOTE: If noise is detected on the link, reduce only the Uplink for optimal signal.