AXELL MBF-40 AMERICAS REPEATER
PRODUCT DESCRIPTION AND USER’S MANUAL
© Axell Wireless Ltd Doc. No. 00071UM Rev. 3.2 49
4.2 Open a Session to the MBF-40 via the OMU II
1. Open a local or remote session to the host OMU II:
• Remote session – open a Browser session in the same subnet as the host
OMU II and enter the IP of the host OMU II (see OMU user manual for
detailed procedure). Enter the OMU II User Name (e.g. axell) and
Password (provided by your system administrator).
• Local session– connect to the OMU II Control Module's USB or Ethernet
ports. Enter the OMU II User Name (e.g. axell) and Password (provided by
your system administrator).
• After accessing an OMU II session, commission the MBF-40 according to the
following section.
Figure 4-3: Connection to OMU II
USB
Ethernet
bl
Connect to EITHER the
USB port OR Ethernet port