User Manual
Table Of Contents
- 1 Introduction
- 2 Installation Requirements
- 3 Repeater Installation
- 3.1 Location Criteria
- 3.2 Standard Repeater Installation
- 3.3 Repeater with Fan Hood Installation
- 3.4 Five-Band System Installation
- 3.5 Grounding
- 3.6 Ensure Good EMV Protection
- 3.7 Fiber Optic Connection
- 3.8 External Alarm and Relay Connections
- 3.9 Power and Backup Battery
- 3.10 Power ON
- 3.11 Closing and Securing the Repeater
- 4 Opening a Session and Navigating GUI
- 5 MBF-40 Commissioning
- 6 MBF-40 Full GUI Description
- 7 Monitoring, Fault Sourcing and Maintenance
- Appendix A - US Specifications
- Appendix B - Canada Specifications
- Appendix C – F/O Cleaning Procedure
AXELL MBF-40 AMERICAS REPEATER
PRODUCT DESCRIPTION AND USER’S MANUAL
© Axell Wireless Ltd Doc. No. 00071UM Rev. 3.2 43
3.9.3 Connecting the Power Source
• Power Source: 115 VAC 60 Hz or -48 VDC
• The -48VDC version of the power supply is designed to turn off if the supply voltage
falls below -36V (±1V). It will turn on again as the supply voltage reaches -43V (±
1V).
• The power supply has a switch which allows it to be set in “on” position or in “stand
by”.
NOTES the following:
• In the stand by position the repeater is still connected to the power supply
but not operational.
• On repeaters mounted in an extended box with two power supplies, both
power supplies needs to be switched on.
3.9.4 115 VAC Power Source
Cable requirements:
• Cable should be NRTL (safety) approved with a minimum of 14AWG (2.5mm) per
conductor.
• For safety, the GND cable must be 10mm longer than the Phase and Neutral
cables.
Connect the power cable to the plinth as show below:
• Phase linked to the Black cable
• Neutral linked to the White
• Ground to the Green where for SAFETY, the GND cable must be 10mm longer
than the Phase and Neutral cables.
Figure 3-34: 115VAC Power Connections