User Manual
Table Of Contents
- 1 Introduction
- 2 Installation Requirements
- 3 Repeater Installation
- 3.1 Location Criteria
- 3.2 Standard Repeater Installation
- 3.3 Repeater with Fan Hood Installation
- 3.4 Five-Band System Installation
- 3.5 Grounding
- 3.6 Ensure Good EMV Protection
- 3.7 Fiber Optic Connection
- 3.8 External Alarm and Relay Connections
- 3.9 Power and Backup Battery
- 3.10 Power ON
- 3.11 Closing and Securing the Repeater
- 4 Opening a Session and Navigating GUI
- 5 MBF-40 Commissioning
- 6 MBF-40 Full GUI Description
- 7 Monitoring, Fault Sourcing and Maintenance
- Appendix A - US Specifications
- Appendix B - Canada Specifications
- Appendix C – F/O Cleaning Procedure
AXELL MBF-40 AMERICAS REPEATER
PRODUCT DESCRIPTION AND USER’S MANUAL
© Axell Wireless Ltd Doc. No. 00071UM Rev. 3.2 39
4. Connect the Fiber(s) to the Fiber Optic Converter(s) inside the repeater:
• Single sector MBF-40 – one optic converter is installed in the repeater.
• MIMO MBF-40 – two optic converters are installed in the repeater (connect
both).
NOTE: Make sure the Fiber is not bent too sharply inside the repeater as to avoid communication
disruptions.
Figure 3-27: Single F/O Connection
Figure 3-28: MIMO Dual F/O Connection
5. Place the Fiber(s) in the rubber seal (for MIMO, run both Fibers in the same rubber
seal).
Figure 3-29: Run Fiber in the Rubber Seal (for MIMO, Run Both Fibers in the Same Rubber Seal)
NOTE: The sleeve (not supplied), together with the rubber seal, meets the protection standard
IP65/NEMA4.
Single F/O Connector
Dual F/O Connectors