User Manual
Table Of Contents
- 1 Introduction
- 2 Installation Requirements
- 3 Repeater Installation
- 3.1 Location Criteria
- 3.2 Standard Repeater Installation
- 3.3 Repeater with Fan Hood Installation
- 3.4 Five-Band System Installation
- 3.5 Grounding
- 3.6 Ensure Good EMV Protection
- 3.7 Fiber Optic Connection
- 3.8 External Alarm and Relay Connections
- 3.9 Power and Backup Battery
- 3.10 Power ON
- 3.11 Closing and Securing the Repeater
- 4 Opening a Session and Navigating GUI
- 5 MBF-40 Commissioning
- 6 MBF-40 Full GUI Description
- 7 Monitoring, Fault Sourcing and Maintenance
- Appendix A - US Specifications
- Appendix B - Canada Specifications
- Appendix C – F/O Cleaning Procedure
AXELL MBF -40 AMERICAS REPEATERS
PRODUCT DESCRIPTION AND USER’S MANUAL
38 Doc. No. 00071UM Rev. 3.2 © Axell Wireless Ltd
3.7 Fiber Optic Connection
WARNING!! Maximum input power should not exceed (zero) 0 dBm
NOTE: Clean the Fiber connectors (receptacles and cables) before connecting. See Appendix C –
F/O Cleaning Procedure for details on F/O cleaning procedures.
Class 1 Laser
This product is equipped with class 1 lasers, as per definition in EN 60825-1.
Caution!!!
Un-terminated optical receptacles may emit laser
radiation.
Do not stare into beam or view with optical instruments.
Use the following over the complete link between the Repeater and OMU:
• Use angled APC connectors at 8deg angle
• APC type ODF connections
Connecting the Fiber Optic Cable
NOTE: The procedure below includes F/O connection instructions for both single sector and for
MIMO topologies.
1. Select type of optic Fiber (Recommended Fiber cable is single mode 9/125).
2. Run the Fiber through a corrugated
sleeve (not supplied). For MIMO models,
route both Fibers through the same
sleeve.
Figure 3-25: Run Optic Fibers through Sleeve
3. Insert the optic Fiber hose fitter (may be
pre-assembled) and route the Fiber
cable(s) via the Fiber input (see front
panel interfaces in section
1.7.2).
Figure 3-26: Route Optic Fiber(s) via the Fiber
Input
Fiber hose
fitter