User Manual

Table Of Contents
AXELL MBF -40 AMERICAS REPEATERS
PRODUCT DESCRIPTION AND USER’S MANUAL
12 Doc. No. 00071UM Rev. 3.2 © Axell Wireless Ltd
2.1.3 RF Cable Installation Guidelines
For all coaxial connections to/from the Repeater use high performance, low-loss,
50 ohm coaxial communication cables.
All cables shall be weather-resistant type.
Cable length determined by the Repeater installation plan. When calculating the
cable length, take into account excess cable slack so as not to limit the insertion
paths.
Make sure the cable and the connector are compatible. Using cables and connectors
from the same manufacturer is helpful.
All connectors must be clean and dry.
Waterproof all outdoor connections using silicon, vulcanizable tape or any other
suitable substance, as moisture and dust can impair RF characteristics
Make sure enough room has been allocated for the bending radius of the cable. RF
cables must not be kinked, cut or damaged in any way.
Connect the RF cable to the antenna tightly but without damaging threads.
Fasten cable tightly to cable ladder or aluminium sheet.
For short length feeder cables, use 1/2”; for longer feeder cables, use 7/8”. Choose
thicker coax cables for lower attenuation. Minimize the length of the coax cables to
reduce attenuation.
Use jumper cable for easy installation. The RF coaxial cable can be substituted at
each end with a jumper cable.
2.1.4 F/O Cable Installation Guidelines
Use the following over the complete link between the Remote and OMU:
Use angled APC connectors at 8deg angle.
APC type ODF connections.
Cable length - determined by the Remote installation plan. When calculating the
cable length, take into account excess cable slack so as not to limit the insertion
paths.
Recommended Fiber-optic cable:
Single mode 9/125