User Manual
Table Of Contents
- 1 Introduction
- 2 Installation Requirements
- 3 MBF-20 Installation
- 4 MBF-20 Setup and Commissioning
- Appendix A: US/Canada Specifications
- Appendix B: Optic Fibre Cables Connections
- Appendix C: F/O Cleaning Procedure
- Appendix D: LED Troubleshooting
MBF-20 AMERICAS REMOTE
PRODUCT DESCRIPTION AND USER’S MANUAL
© Axell Wireless Ltd User Manual Doc No. 00068UM Rev. 2.4 33
Wet Cleaning
ATTENTION!
Invisible laser radiation might be emitted from disconnected fibers or
connectors. Do not stare into beams or view directly with optical instruments.
1. Lightly moisten a new lint-free wipe with 99% isopropyl alcohol. (Step 1 below).
Tip: Have a dry lint-free swab available for immediately drying after performing the wet-cleaning.
2. Lightly press and turn a clean lint-free swab in the moistened area of the wipe to
moisten the swab. It is important that the swab is not too wet. (Step 2 below).
3. Insert the moistened lint-free swab into the bulkhead adapter. Lightly press and
rotate several times in the same direction. (Step 3 below).
Wet-Cleaning Technique
4. Immediately use a dry lint-free swab to clear any remaining alcohol residue.
NOTE: Do not re-use any of the wipes and/or swabs. Dispose of them properly.
5. Follow steps 3 to 6 of Dry Cleaning above
6. Re-inspect the fibre using the Fibrescope. On the PC monitor, verify that there is no
contamination present on the connector end-face.
7. If the fibre is still dirty, go back to step 1 (Wet Cleaning) and repeat the entire
process.
NOTE: The entire wet/dry cleaning cycle should only be used twice, if the fibre is still dirty after two
cycles of wet/dry cleaning seek advice from the Axell Wireless Support Desk.
Step 1
Step 2
Step 3