Appendix C: F/O Cleaning Procedure
NOTE: The process is demonstrated on an OMU F/O module and is similar to all F/O equipment
supplied by Axell.
Tools:
Tool Description Illustration
Fibrescope connected to a PC running the
appropriate viewing software.
It is highly recommended that some form of
fibre viewing equipment such as a Fibrescope is
used to ensure that all fibre connections are
clean before termination; failure to do so could
result in poor system performance
Lint-free swabs (box), Axell P/N 99-000127
Lint-free wipes (pack) Axell P/N 99-000125
Fujikura “One Click” cleaner, Axell P/N 98-
900004.
99% isopropyl alcohol (can), Axell P/N 99-
000126
Cletop type S Cassette Cleaner, Axell P/N 98-
900068