20 User Manual Doc No. 00068UM Rev. 2.4 © Axell Wireless Ltd
Figure 4-5: Example of MBF 20 Quad Band Configuration window
3. The General area provides basic identification and status information and enables
assigning an identifiable name:
• Received level – opto signal level at the MBF-20 (from the optic fibre)
• Tag – identifiable name currently assigned to the unit. Click the icon
to change the name.
• Model – unit type, frequencies and Master (M) or Slave (S)
• ID – unique serial number associated with this unit (automatically
assigned by AEM)
• Opto Loss Compensation – compensation allocated on the UL during the
Optical Adjustment procedure
4. In the Downlink:
• Verify the Amplifier for each band is ON.
• Set Attenuation to maximum value (15dB).
• Lower the Attenuation level step by step until the desired Output power
level is reached. (Zero attenuation = maximum gain).
• Verify the Amplifier Saturation is GREEN.