User Manual

MBF-20 AMERICAS REMOTE
PRODUCT DESCRIPTION AND USER’S MANUAL
© Axell Wireless Ltd User Manual Doc No. 00068UM Rev. 2.4 19
4. If necessary, perform adjustment on the link(s) by doing the following:
Checkmark the node(s)or click on one of the buttons for other selection
options.
Click Adjust.
The status of the adjust procedure for each selected node, and the amount of
compensation (for completed adjustment procedures) is displayed in the
corresponding row(s).
5. Perform the RF balancing according to the following section.
4.3 MBF-20 RF Balancing
The MBF-20 RF Balancing procedure can be performed manually (the automatic option
specified in section 4.3.2 will be available in the future) via the OMU II web interface.
4.3.1 Manual MBF-20 RF Balancing
The manual balancing procedure consists of the following steps:
Verifying a DL RF output level of 18/23dBm by setting the required DL attenuation of
the signal.
Setting the UL attenuation according to the DL.
In case of noise, adjusting the UL attenuation to reduce noise
To balance the MBF-20 UL and DL outputs
1. Access the MBF-20 Configuration window:
Click on the Nodes button. The below pane appears
Click Control next to the node to be balanced.
2. The resulting pane can be displayed in two views:
Basic default view (Basic button)
Advanced provides more information (Advanced button)
The dialog below shows an example of the Basic (default) view.