3 MBF-20 Installation
A maximum of 24 MBF-20 dual/quad units can be connected to a single OMU II system.
The number varies depending on the OMU II hardware configuration and any additional
installed high-power fibre-fed remotes.
Note the following:
Up to four MBF-20 remotes can be installed per OMU II node (via an Optic
Splitter).
When multiple remotes are installed at a single node, each remote must
support a unique UL colour wave (MBF-20 model specific).
Each MBF-20 is connected towards an OMU II Optic Splitter module
This section describes two types of installation procedures:
Single MBF-20 unitsection 3.1.
Quad-band assembly consisting of two MBF-20 unitssection
3.2.
3.1 Dual-band Installation
The physical installation consists of mounting the unit, connecting antennas, power and
the optic fibre. Once the physical installation is complete, the unit is automatically
identified by the OMU II and can be setup from the OMU II side. Not setup procedure is
required from the remote site.
3.1.1 Overview
NOTE: The service antenna(s) can be positioned and installed (without being connected to the
Remote) at any time either before or after remote installation
1. Unpack the Remote kit.
2. Connect the Power Supply to the bracket (do not connect power).
3. Mount the Bracket assembly on the wall.
4. Mount the Remote onto the bracket.
5. Clean and Connect the Fibre Optic cable.
6. Connect the antenna(s).
7. Power-on the Remote.
3.1.2 Required Tools and Materials
The following is required in order to install the Remote:
Standard professional tool box
F/O cleaning kit