MBF-20 AMERICAS REMOTE
PRODUCT DESCRIPTION AND USER’S MANUAL
20 User Manual Doc No. 00068UM Rev. 2.4 © Axell Wireless Ltd
Figure 4-5: Example of MBF 20 Quad Band Configuration window
3. The General area provides basic identification and status information and enables
assigning an identifiable name:
Received level opto signal level at the MBF-20 (from the optic fibre)
Tag identifiable name currently assigned to the unit. Click the icon
to change the name.
Model unit type, frequencies and Master (M) or Slave (S)
ID unique serial number associated with this unit (automatically
assigned by AEM)
Opto Loss Compensation compensation allocated on the UL during the
Optical Adjustment procedure
4. In the Downlink:
Verify the Amplifier for each band is ON.
Set Attenuation to maximum value (15dB).
Lower the Attenuation level step by step until the desired Output power
level is reached. (Zero attenuation = maximum gain).
Verify the Amplifier Saturation is GREEN.
Views
General
Band
information
UL setting
DL setting