4 MBF-20 Setup and Commissioning
The MBF-20 Remote is a Plug-and-Play solution that requires no configuration at the
remote installation site. The setup procedure described in this section is performed by
opening a management session to the host OMU II unit.
The MBF-20 Setup and Commissioning consists of:
1. Accessing the MBF-20 via OMU session.
2. Verifying and (if necessary) performing Optical Loss Adjustment.
3. Setting the required RF attenuation and gain levels.
4. Assigning the unit a recognizable name according to its location.
4.1 Open a Session to the MBF-20 via the OMU II
1. Open a local or remote session to the host OMU II:
Remote session open a Browser session in the same subnet as the host
OMU II and enter the IP of the host OMU II. Enter the OMU II User Name
(axell) and Password (provided by your system administrator).
Local sessionconnect to the OMU II Control Module USB port or Ethernet
port. Enter the OMU II User Name (axell) and Password (provided by your
system administrator).
Figure 4-1: Connection to OMU II
The OMU II main screen appears (see example below).
Figure 4-2: OMU II Main window
USB cable
Ethernet cable
Connect to EITHER the
USB port or Ethernet port