© Axell Wireless Ltd User Manual Doc No. 00068UM Rev. 2.4 13
3.1.5 Antenna Connections
CAUTION!!
• Do not connect the antenna cables to the remote before verifying the installation
parameters.
• Do not power-up the remote without either the antennas being connected or the
antenna connections terminated with dummy loads..
To connect the antennas to the MBF-20 Master
1. Install the antenna cables along their path to the Remote, and connect them to the
Antennas.
NOTE: Be sure to use low loss cables.
2. Connect the Service antenna(s) to any of the MBF-20 Master MOBILE ports. (Mobile
antenna specifications and installation criteria are described in section 2.2).
3. Terminate any unused service antenna port.
4. Verify all RF connectors are tightened and the cables and antennas are secured.
Figure 3-3: MBF-20 Single/Dual-Band Antenna Connections
RF Service
Antenna
RF Service
Antenna