User's Manual
Table Of Contents
- 1 INTRODUCTION
- 2 BOOSTER PRE-INSTALLATION REQUIREMENTS AND GUIDELINES
- 3 BOOSTER MOUNTING AND INSTALLATION
- 3.1 Booster Installation Overview
- 3.2 Unpacking and Package Contents
- 3.3 Mounting the System
- 3.4 Connections
- 4 SETUP AND COMMISSIONING
- 5 ADMINISTRATIVE OPERATIONS
- 6 MONITORING AND TROUBLESHOOTING
SMR 700 800 HIGH POWER PS NFPA CLASS B SIGNAL BOOSTER
PRODUCT DESCRIPTION AND USER’S MANUAL
Cobham Wireless – Coverage
Date: 23-Nov-16
www.cobham.com/wireless
Doc. No.00060CDUM Rev. 3.4 Page | 56
6 MONITORING AND TROUBLESHOOTING
The Booster provides panel LEDs, external alarms connectors and two types of (WEB GUI) alarm screens
used for viewing status and for alerting and troubleshooting the causes of Booster faults or failure.
The following sections provide a description of the various alarms, a description of possible faults and
corrective actions. In addition, the relevant screens for viewing the alarms are described.
6.1 Booster Panel LEDs
Two status LEDs are located on the Booster panel:
• Upper LED - UL status for one or two bands
• Lower LED - DL status for one or two bands
Figure 6-1. UL and DL Status LEDs located on Underside Panel
The LEDs provide the following information on status and possible faults:
Color Description Corrective Action
Green Normal (UL or DL) operation -
Red Power failure (in UL or DL)
Corrective action: Turn off the Booster (this action
causes a reset of the function), and turn it on anew.
If the fault resumes, replace the unit.
Blinking
Orange/red
Mute - either user- or system-
initiated.
(System initiated mute may be
due to isolation problem or
temperature).
Check gain of the booster, if gain is minimum, then it
is an isolation problem. Improve isolation.
Turn OFF the Booster (resets the function), and turn
it ON again. If the fault resumes, replace the unit.
UL Status LEDs
DL Status LEDs