UL Gain Δ - used for noise control. Sets the difference between UL and DL
gain.
UL Measured Ch. Gain - measured UL Gain (dB) for the selected sub-
band.
7. Click Send (top window area option).
8. After the channels have been configured and the required coverage is attained for
the location, verify that no Alarms are generated:
Click the Alarms tab
Verify that all the indicators are GREEN in the Alarms tab.
4.3.3 Setting Date and Time
It is important to set the correct date and time on the unit since this provides the
timestamp for each logged event and alarm.
To set the Repeaters date and time
1. Click on CMU in the tree pane, click on Date & Time in the menu bar.
2. Set the date and time parameters and click on Set.
3. Click Reset CMU at the top of the Main window.