User's Manual
Table Of Contents
- 1 Introduction
- 2 Antenna Specifications and Installation
- 3 Installing the Repeater
- 3.1 Overview of the Installation Procedure
- 3.2 Required Tools and Materials
- 3.3 Unpacking
- 3.4 Mounting the Repeater
- 3.5 Grounding
- 3.6 Verifying Isolation between Donor and Mobile Antennas
- 3.7 Verifying the Link between the BTS and the Repeater
- 3.8 Antenna Connections
- 3.9 Powering Up the Repeater
- 3.10 External Alarm Connections
- 4 Initial Setup and Commissioning
- 5 Administrative Operations
- 6 Monitoring and Troubleshooting
- Appendix A: Specifications (@+25°C)
Axell D-SBR 3709S Repeater
PRODUCT DESCRIPTION AND USER’S MANUAL
© Axell Wireless Ltd
Doc PN 00038UMCD Rev. 1.6 19
4. Click the Properties button. The Networking tab appears.
5. In the Items list, double-click the “Internet Protocol Version 4 (TCP*IPv4)” item.
6. The Internet Protocol Version 4 (TCP/IPv4) Properties dialog appears.
Note: The Repeater is supplied with the default IP address 192.168.1.253.
7. Assign your computer an IP address in the same subnet, in order to communicate
with the unit.
• In the IP address area:
• Enter the IP address 192.168.1.x, where ‘x’ can be any number between 2
and 250 inclusive. For example, (192.168.1.9)
• Define the subnet mask as shown (255.255.255.0)
• Click OK. The computer communication parameters are now defined and
you can open a session to the Repeater.