The front panel Alarm port supports two alarm connections from two external sources.
Note the following:
The alarms can be connected any time, before or after the system is powered-on.
The alarms cable is supplied in the product kit.
The connections must conform to the following load restrictions: maximum
repetitive reverse voltage: 28V; Impedance load: “0” = 0V or GND; “1” = 3.8V - 28V
After connecting, enable the External Alarms via the Web GUI CMU option, External
Alarms tab.
3
2
1
4
5
6
7
Ext
. Alarm 1 (black)
Ext. Alarm 2 (red)
Ext. Alarm 1 GND (orange)
Ext. Alarm 2 GND (blue)
Alarm
The Alarm connector pinout is described below.
Wire
color
Signal
Pins
number
Operation
Black
Ext Alarm_1
IN
1
Triggers Alarm ID 1
Orange GND 5 Ground, galvanic short to Repeater chassis.
Red
Ext Alarm_2
IN
2
Triggers Alarm ID 2
Blue GND 6 Ground, galvanic short to Repeater chassis.