PRODUCT DESCRIPTION AND USER’S MANUAL
60 DIGImini Americas User Manual Rev 3.5 © Axell Wireless Ltd
6.7 Communication and System Parameters
NOTE: All CMU Configuration options (tabs visible in screenshot below) require a CMU be connected
to the DIGImini Repeater. If a CMU is not connected the GUI will not display the CMU tab.
The Communication Configuration tab provides the Modem, IP, AEM and SNMP trap configuration
parameters.
This section describes how to access the dialog. The following sub-sections provide detailed
information on each configuration option.
6.7.1 The Communication Configuration Tab
To access the Communication Configuration tab
In the left tree pane, click CMU. From the available tabs in the work area, choose the
Communication Configuration tab.
6.7.2 IP Address Configuration
The Repeater supports both Static and DHCP addresses. A unique technology enables applying both
types to the same Ethernet port. Both addresses may enable local and remote management.
Local IP Address Static IP assigned by the user to the system. The default Static IP address is
192.168.1.253. It is highly recommended to preserve this setup. In case of a change, make sure
you record the newly assign IP.
DHCP Address address assigned by DHCP server used for remote management via an
Ethernet connection.
IP Address settings
Modem parameters
SNMP IP
destinations
Trap sending
frequency
SMS destinations
mobile numbers
AEM
configuration