6.4.5 DMCU Dry Contacts
The DMCU provides two types of alarms:
X2 External Alarms IN used to acquire status of connected external devices or sensors such as
Door-open, air-conditioner, temperature, etc. These alarms are also defined and enabled through
the GUI. If an alarm is generated, it is displayed in the Alarms Log screen.
X1 Summary Alarm OUT indicates a fault in the Repeater. It is activated any time any error is
generated in the Repeater and can be connected to an external device.
To connect and configure the dry-contacts
1. Wire the dry-contacts according to section
6.4.5.1.
2. Configure the external alarms according to section
6.6.3.
3. You may monitor the external alarms log according to section
6.9.1.
6.4.5.1 DMCU Dry-Contact Wiring
Wire color Signal
Pins number
J1
J2
White
Ext Alarm_1 IN
1
1
Brown
GND
2
5
Green
Ext Alarm_2 IN
3
2
Yellow
GND
4
6
Grey
Ext Alarm_3 IN
5
-
Orange
Dry contact Out
6
7
Blue
Dry contact NC
7
4
Red
Dry contact NO
8
3
Connectors view