User's Manual
Table Of Contents
- 1 Introduction
- 2 Antenna and Repeater Installation Requirements
- 3 Dual-Band Repeater Installation
- 4 Two Dual Units (Quad-band) Installation
- 4.1 Overview
- 4.2 View of the Quad Band Installation
- 4.3 Required Tools and Materials
- 4.4 DIGImini Tri/Quad-band Kit
- 4.5 Upgrading to a Quad-Band System
- 5 Setup and Configuration
- 6 DMCU Installation and Management
- 1
- 6.5.2.1 Band Tabs
- 6.5.2.2 CMU Tabs
- 6.5.2.3 Operation Buttons
- 6.6 Basic Configuration Procedures
- 6.7 Communication and System Parameters
- 6.8 DMCU Administration
- 6.9 CMU Monitoring and Troubleshooting Options
- Appendix A: Specifications (@+25 C)
AXELL DIGIMINI- AMERICAS REPEATER
PRODUCT DESCRIPTION AND USER’S MANUAL
© Axell Wireless Ltd DIGImini Americas User Manual Rev 3.5 41
To adjust the signal levels and configure the channels
1. In the left pane (Topology Tree), select the supported band configuration (e.g. 850-1900) which
includes the Band item whose sub-bands are to be configured.
2. Click the Control and Params tab. For dual/triple/quad band configurations, click the required
band for configuration and the corresponding pane appears.
The window is divided into the following areas:
• System – overall parameters for the selected service.
• Filter definitions – used to define up to six sub-bands and their RF parameters.
• Sub-bands view – graphical display of defined sub-bands for the service.
Note: You may define up to Six sub-bands per 2 bands, e.g. 4 sub-bands for the 850MHz band and 2
sub-bands for the 1900MHz band (see section
5.2.5 for details).
Figure 5-4. Params and Control Tab (example shows quad-band)
3. Set the System Level parameters:
• Verify that the RF Transmission Enable parameter is checked.
• Set the Max Composite DL Output Power according to your site requirements and click
Send. The Measured Composite DL Output Power is displayed in the adjacent field.
If the composite output power exceeds the defined value, the Smart ALC feature begins working.
• Set the Max Composite UL Output Power according to your site requirements.
Additional parameters (not required for initial setup) are:
Service level
parameters
Click Send with
each change
Sub-band
definition options
Defined
band channels
Select the band
to configure