User's Manual
AXELL DIGIMINI- AMERICAS REPEATER
PRODUCT DESCRIPTION AND USER’S MANUAL
84 Doc PN 4000003431 Rev. 3.8 © Axell Wireless Ltd
6.8.4.5 Deleting a User
To delete a user
1. From the Tree Pane Select Users. The list of users is displayed in the User's Pane.
2. Select the User to be deleted in the list.
3. From the User's Pane, click Del. An authorization message dialog box is displayed.
4. Click Yes. The User’s name is removed from the list.
6.9 CMU Monitoring and Troubleshooting Options
In addition to the Repeater failure indications provided by the DIGImini (described in Chapter 5.3 -
Monitoring and Troubleshooting), when a DMCU is connected the following additional monitoring
options are provided:
• DMCU Status LEDs located on front panel
• Alarms Log – used to view a record of past generated alarms and events
• CMU Alarms – used to view record of generated external alarms
6.9.1 DMCU LED Troubleshooting
The DIGImini repeater includes six LEDs on its front panel (see 1.6.1). The following table provides
a description of the LED troubleshooting procedures.
Indicator Description
Band Specific LED
(e.g. 850/1900)
One Indicator per band :
RED Steady - service muted due to
general fault
Blinking – service muted by user
ORANGE
Blinking – service initiating
on power up or reset
Steady – high DL/UL signal or VSWR
GREEN and
ORANGE
Blinking- Reduced gain by IMOP
GREEN Blinking – DL power below threshold
Steady - normal service operation
(ETHERNET) MNG Green Blinking – normal operation of CCD
(ETHERNET)
MODEM
• Green Steady - modem is either not defined, or defined modem is
operating normally.
• Orange Steady– modem is trying to connect
• Red Steady– modem failed to connect