User's Manual
AXELL DIGIMINI- AMERICAS REPEATER
PRODUCT DESCRIPTION AND USER’S MANUAL
50 Doc PN 4000003431 Rev. 3.8 © Axell Wireless Ltd
• Oscillation Prevention Enable - Enables oscillation detection mechanism that maintains
repeater functionality.
• Temperature - Displays Repeater ambient temperature.
• DL Output Threshold Delta (dB) - the delta from the set Composite Output Power, below
which the alarm 'Donor power is too low' is activated.
For example, if the DL Output Threshold value is set to 8dB, when the Measured Composite
DL output power is 8dB less than the set Composite Output Power, an alarm is generated.
• Meas. Composite DL Output Power – displays the currently measured output signal level.
4. To configure each sub-band:
• Checkmark Enable. The configuration parameters in that row will be available.
• In the Downlink area, set the Start and Stop DL Frequency (MHz). (The Uplink Start and
Stop frequencies will be automatically allocated.)
The defined BW will be displayed in the BW KHz column (to the left of the Start Frequency).
• Set the (Downlink) Max Gain as follows: by default, the MAX Gain (DL) parameter is set to
its highest level (73dB). Change the Channel Max Gain (DL) according to the
measured/calculated input power and isolation measurements.
• The recommended Maximum Gain setting is approximately 15 dB less than the isolation
between the service and donor antennas.
5. If the site NOISE LEVEL is high enough to cause interference, adjust the noise level as follows:
• Adjust the Gain Delta parameter – this sets the delta between the uplink and downlink gain
(so the uplink gain is relatively lower than the downlink gain.
• Click Send.
• Repeat the procedure until the desired coverage is achieved.
6. More information on parameters for the selected sub-band:
• DL Set Ch. Max. Gain Sets the power for the antennas. The value is about 15 dB less than
the isolation between the donor antenna and the mobile antenna.
The Value defined in the DL path is reflected in the UL path, however to define
different UL and DL path values the Gain Delta parameter is used and its defined value
is added to the UL value.
• DL Measured RSSI - measured DL signal.
• DL Measured Ch. Gain - measured DL Gain (dB) for the selected sub-band.
• DL Measured Ch. Power - measured Power (dBm) for the selected sub-band.
• UL Gain Δ - used for noise control. Sets the difference between UL and DL gain.
• UL Measured Ch. Gain - measured UL Gain (dB) for the selected sub-band.
7. Click Send (top window area option).