6.4.5 DMCU External Alarms
The DMCU provides two External alarms connections, used to acquire status of connected external
devices or sensors such as Door-open, air-conditioner, temperature, etc. These alarms are also defined
and enabled through the GUI. If an alarm is generated, it is displayed in the Alarms Log screen.
To connect and configure the external alarms
1. Wire the external alarm connectors according to section
6.4.5.1.
2. Configure the external alarms according to section
6.6.3.
3. You may monitor the external alarms log according to section
6.9.1 6.9.2.
6.4.5.1 DMCU External Alarms
Wire color Signal
Pins number
J1
J2
White
Ext Alarm_1 IN
1
1
Brown
GND
2
5
Green
Ext Alarm_2 IN
3
2
Yellow
GND
4
6
NOTE: Pins 5-8 (J1) and Pins 3,4,7 (J2) are not in use.
Connectors view
Figure
6-5. DMCU External Alarms
Cable side view
1
Conn: 1702100004
J1
1
2
34
5
6
7
J2
Cable side view
Conn: 1427000002