User's Manual

© Axell Wireless Ltd
5.4
CMU Software Upgrade
The procedure described in this section is used to upgrade the repeater CMU.
NOTE: This procedure is performed for every new management version.
The CMU SW upgrade procedure consists of loading the new software version and
installing it in the CMU. The CMU can store two versions on two separate data banks
enabling restore to a previous version.
To Upgrade the CMU SW
1. In the Tree Pane, select
CMU
f
ollowing screen appears (the Browse field will be empty).
2.
Choose and save the file onto the Repeater:
(1) Click Browse
to search for the location and choose the new software file. It
will be displayed adjacent to the Browse button.
(2)
Select the bank where the file will be stored. (Before it is populated the
bank will be named ‘slot’. After it is populated, it will take on the name of the
stored software version). Any existing software file will be replaced.
(3) Press Upload to save th
software files to choose from will be listed.
AXELL D-MBR 3007-3008-
PS NFPA REPEATER
PRODUCT DESCRIPTION AND USERS MANUAL
UMCD00013 Rev 2.2
CMU Software Upgrade
The procedure described in this section is used to upgrade the repeater CMU.
NOTE: This procedure is performed for every new management version.
The CMU SW upgrade procedure consists of loading the new software version and
installing it in the CMU. The CMU can store two versions on two separate data banks
enabling restore to a previous version.
CMU
and click the Axell CMU SW Upgrade
tab. The
ollowing screen appears (the Browse field will be empty).
Choose and save the file onto the Repeater:
to search for the location and choose the new software file. It
will be displayed adjacent to the Browse button.
Select the bank where the file will be stored. (Before it is populated the
bank will be named slot’. After it is populated, it will take on the name of the
stored software version). Any existing software file will be replaced.
(3) Press Upload to save th
e file to the selected bank (slot).
The available
software files to choose from will be listed.
PS NFPA REPEATER
PRODUCT DESCRIPTION AND USER’S MANUAL
44
The procedure described in this section is used to upgrade the repeater CMU.
The CMU SW upgrade procedure consists of loading the new software version and
installing it in the CMU. The CMU can store two versions on two separate data banks
tab. The
to search for the location and choose the new software file. It
Select the bank where the file will be stored. (Before it is populated the
bank will be named slot. After it is populated, it will take on the name of the
stored software version). Any existing software file will be replaced.
The available