4.4.6 Connection to External Battery
ATTENTION!! The Externally Battery must meet the following requirements:
• Valve-Regulated Lead-Acid (VRLA)
• Gelled Electrolyte (gel) and Absorbed Glass Mat (AGM) Batteries or LEAD ACID
Connect the external battery to the Charger Battery connector:
Figure 4-7 External Battery Connections
4.4.7 Charger Alarm Connections
The Charger supports three dry contact alarms that are connected to the Fire Department Control
Box:
• AC Input Fail*
• Low Battery
• Battery Charger Fail*
Figure 4-8. Charger Connections Architecture
*Optionally, Battery Charger Fail and AC Input Fail can be connected to the Booster alarm connector for
monitoring).