© Axell Wireless Ltd UMCD00013 Rev 2.2 35
4.4 Configuring the External Alarms
Any connected external alarms (section 3.9) must be enabled and configured according
to the instructions provided in this section.
To configure external alarms
1. Click on CMU in the tree pane and select the External Alarms tab. The following
dialog appears.
Figure 4-6. External Alarm Configuration Dialog
2. For each connected alarm:
Checkmark the Active checkbox.
Verify the alarm Normal Mode is set to Low.
Set the alarm Severity as Critical, Major or Minor
In the Description field, assign the alarm an identifiable name (e.g. Door
open).
NOTE: Triggered external alarms are displayed in the Axell-CMU-Alarms tab.