User's Manual

Table Of Contents
AXELL 3307D REPEATER
PRODUCT DESCRIPTION AND USER’S MANUAL
8 © Axell Wireless Ltd
3.1.4 RF Cable Installation Guidelines
Required:
For all coaxial connections to/from the Repeater - high performance, flexible, low loss 50Ω
coaxial communications cable.
All cables shall be weather-resistant type.
Cable length - determined by the Repeater installation plan. When calculating the cable length,
take into account excess cable slack so as not to limit the insertion paths.
3.1.5 Power Requirements
3.1.5.1 Overcurrent Protection
A readily accessible, listed branch circuit over current protective device, rated 20 A, must be
incorporated in the building wiring.
3.1.5.2 North American Power Wiring
Select a power supply cord that is UL Listed and CSA Certified: 3 - conductor, 18 AWG, terminated
in a molded on plug cap rated 125 V, 15 A, with a minimum length of 1.5m [six feet] but no longer
than 4.5m.
3.1.6 Grounding Wires Requirements
Requirements for grounding wires
Protective grounding conductor - should be aluminum with cross-section 10AWG.
Lug of the protective grounding conductor - should be aluminum
Washers and screw - should be high Cr stainless steel, or 12% Cr stainless steel, or Cr on, Ni on
steel, tin on steel
3
3
.
.
2
2
O
O
v
v
e
e
r
r
v
v
i
i
e
e
w
w
o
o
f
f
t
t
h
h
e
e
I
I
n
n
s
s
t
t
a
a
l
l
l
l
a
a
t
t
i
i
o
o
n
n
P
P
r
r
o
o
c
c
e
e
d
d
u
u
r
r
e
e
NOTE: The Donor and Mobile antennas can be positioned and installed (without connection to the
Repeater) at any time either before or after mounting and grounding the Repeater.
1. Unpack the Repeater kit.
2. Mount the Repeater on the wall.
3. For GPS/GPRS modems - open the Repeater and insert the SIM card.
4. Ground the Repeater.
5. If you have not already done so, position and install the Base and Mobile antennas in the relevant
locations.
6. Before powering up the Repeater:
Verify isolation between the donor and mobile antennas
Verify link between the BTS and Base Repeater.
7. Connect the antennas to the Repeater.
8. Power-up the Repeater.
9. Optional - connect the external alarms. This can be done at any time, before or after powering up
the Repeater.