5.2.2 Two Section Notch Filter (02-010401)
5.2.2.1 Description
Fitted in Unit 2 after the amplification stages is a 2 element notch filter (one in downlink,
one in uplink), which is designed to reject the uplink frequencies in the downlink path
and vice-versa. The notch filter is not required for Unit One as the rejection from the two
series bandpass filters as apposed to one, is sufficient to meet the specification.
5.2.2.2 Technical Specification (Uplink)
PARAMETER SPECIFICATION
Frequency range: 485.2-485.6 MHz
Stopband: 482.2 – 483.6MHz
N. of sections: 2
Attenuation: >40dB @ 482.2MHz
Insertion loss: 0.5dB
VSWR: Better than 1.2:1
Connectors: SMA
Power Handling: 50W maximum
operate
:
-10°C to +55°C
Temperature
range:
store: -30°C to +70°C
Weight: <3 kg
Size: 384 x 82.5 x 56.4mm
5.2.2.3 Technical Specification (Downlink)
Frequency range: 482.2-483.6 MHz
Stopband: 485.2-486.6MHz
N. of sections: 2
Attenuation: >40dB @ 485.2MHz
Insertion loss: 0.5dB
VSWR: Better than 1.2:1
Connectors: SMA
Power Handling: 50W maximum
operate: -10°C to +55°C Temperature
range:
store: -30°C to +70°C
Weight: <3 kg
Size: 384 x 82.5 x 56.4mm